In order to find a solution, one must first understand the problem

Hip Revision

Current Concepts & Solutions

Cemented Fixation

Implant is affixed into the femoral canal using cement to aide in rapid initial fixation.

Highly polished or rough coated finishes

 
 

Cemented Stem Extraction

Proximal forces applied to the prosthesis, thereby breaking the cement-implant interface.

Progressive and systematic removal of embedded cement using chisels, osteotomes or ultrasonic cutters.

OPERATIVE TECHNIQUES ESTABLISHED

Uncemented Fixation

Implant is press-fit into the femoral canal and surface engineered to promote boney ingrowth.

Rough surfaced or HA coated finishes

 
 

Uncemented Stem Extraction

Clearing as much of the circumferential fixation at the proximal portion of the implanted prosthesis.

Use of flexible osteotomes and cutters to blindly drive down the anterior and posterior profiles of the implant.

OPERATIVE TECHNIQUE NOT ESTABLISHED

 
pexels-jonathan-borba-3259624.jpg

Transforming Healthcare

  • StemX is the first and only complete system for tackling uncemented hip revision

  • StemX can be used with any surgical approach, the bespoke cutting tools target the distal tip of the implant and break the implant-bone interface with an average bone loss of 1-2mm circumferential to the prosthesis

  • Surgeons can remove the need for an extensive trochanteric osteotomy, circlage wiring and expensive revision implants. In most cases, a larger primary implant is used following the initial implant extraction

  • Patient recovery and surgical time significantly reduced

pexels-anna-shvets-4483327.jpg

Key Design Attributes

  • Cutting tools delivered at the implant-bone interface

  • No need for extensive trochanteric osteotomy

  • Will remove any well-fixed uncemented hip implant

  • Non-power driven

  • Does not require image intensifiers

  • Leaves cavity in femur to accommodate similar primary implant

  • Simple to use

  • Simple to train

Screenshot 2021-03-15 at 10.31.55.png

StemX targets the outer profile of the hip implant before a single cut is made.

Universal Targeting Device ensures all cuts are delivered at the bone-implant interface

Screenshot 2021-03-15 at 10.34.51.png

Historically difficult medial and lateral profiles cleared with minimal bone loss.

Universal targeting device ensures all cuts are delivered at the bone-implant interface

Screenshot 2021-03-15 at 10.39.46.png

Stem removed leaving cavity similar to extracted prosthesis outside diameter.

Significant reduction in surgical time, surgical cost & time to patient discharge